| action= | Explanation | Parameters |
|---|---|---|
| defreeze | Unfreezes the camera after Terminate Recording (TR) occurred and resumes recording. | |
| delete_reference_image | Delete current reference image. Only available as administrator under /admin/rcontrol. |
|
| delete_system_messages | Delete and reset all system messages. Only available as administrator under /admin/rcontrol. |
|
| emailcurrent | Sends the current image by e-mail using the e-mail profile specified by id or name. |
|
| emaillastevent | Sends the last event image by e-mail using the e-mail profile specified by id or name. |
|
| errorack | Acknowledges an error notification. Only available as administrator under /admin/rcontrol. |
|
| eventack | Acknowledges an event. | |
| exportstatistic | Triggers an export of the statistic data generated by MxAnalytics. | |
| format_device | Format flash device with MxFFS volumes for Recording and/or MxAnalytics. Only available as administrator under /admin/rcontrol. |
|
| ftpcurrent | Sends the current image to the FTP server using the FTP profile specified by id or name. |
|
| ftplastevent | Sends the last event image to the FTP server using the FTP profile specified by id or name. |
|
| generate_reference_image | Save current image as reference image. Only available as administrator under /admin/rcontrol. |
|
| getrs232 | Prints text received from the RS232 interface. |
|
| getrs232hex | Prints text received from the RS232 interface in hex notation. |
|
| gettemp | Gets the camera's internal temperature. | |
| gettext | Replace variables in message and print it as plain text. |
|
| irledsoff | Switches all infrared LEDs off. | |
| irledson | Switches all infrared LEDs on. The optional time parameter switches the LEDs off after the specified number of seconds. |
|
| irledsstring | Switches the infrared LEDs specified in the leds parameter. If no string is specified, the IR LEDs will be switched to default. The optional time parameter switches the IR LEDs off after the specified number of seconds. |
|
| ledsdefault | Switches LEDs to default. | |
| ledsoff | Switches all LEDs off. The optional time parameter switches the LEDs back to default after the specified number of seconds. |
|
| ledson | Switches all LEDs on. The optional time parameter switches the LEDs back to default after the specified number of seconds. |
|
| ledsstring | Switches LEDs specified in the leds parameter. If no string is specified, the LEDs will be switched to default. The optional time parameter switches the LEDs back to default after the specified number of seconds. |
|
| list_plex_recording_targets | Lists the event recording targets provided by supported expansion devices. Set the output parameter to media_types to retrieve the list of supported media types instead. Only available as administrator under /admin/rcontrol. |
|
| mailboxdb_delete | Will delete an entry from the mailbox db, only. It will not erase the actual recording on the event storage. Specify the message using its sequence and event number. Only available as administrator under /admin/rcontrol. |
|
| mailboxdb_reset | Delete all entries in the mailbox database! Only available as administrator under /admin/rcontrol. |
|
| mailboxdb_set_seen_flag | Allows to change the "seen flag", whether a message has been reviewed, for the message given by its sequence and event number. This has to be followed by the flag value. Zero (0) is for unseen messages. Other values for seen messages. |
|
| message | Sends the message specified in the name parameter using the MxMessageSystem. The message is distributed within the current LAN (=range global). |
|
| mxffs_archive_delete | Delete MxFFS archive files on the file server, and reset current transfers and statistics! Attention: You will immediately loose all archived recordings! Only available as administrator under /admin/rcontrol. |
|
| mxffs_archive_delete_without_reset | Delete MxFFS archive files on the file server only. No reset of the statistics queue! Attention: You will immediately loose all archived recordings! Only available as administrator under /admin/rcontrol. |
|
| mxffs_archive_reset_tq | Reset all queued MxFFS archive transfers. Only available as administrator under /admin/rcontrol. |
|
| mxffs_archive_reset_stats | Reset MxFFS archive statistics. Only available as administrator under /admin/rcontrol. |
|
| mxffs_archive_resync | Synchronizes the camera's internal MxFFS block recordings with the archive content by transferring missing blocks (asynchronuous transfer). Only available as administrator under /admin/rcontrol. |
|
| notifycurrent | Sends a network message (IP Notify) with the status of the current image. |
|
| notifylastevent | Sends a network message (IP Notify) with the status of the last event image. |
|
| pancenter | Sets the pan position to the center of the current view. | |
| prepare_format | Prepare format of storage targets. DISABLES RECORDING on selected target or all USB, SD and CF devices and reboots the camera, if required for formatting. Only available as administrator under /admin/rcontrol. |
|
| putrs232 | Sends text specified in the rs232outtext parameter to the RS232 interface. |
|
| reboot | Reboots the camera. Only available as administrator under /admin/rcontrol. |
|
| recording_targets_info | Shows information about available recording targets. When used with check option, tests for newly connected hardware. Only available as administrator under /admin/rcontrol. |
|
| resetconfig | Resets the configuration to factory defaults. Only available as administrator under /admin/rcontrol. |
|
| resetstatistic | Resets statistic data generated by MxAnalytics. | |
| restoreconfig | Restores the current configuration from flash. Only available as administrator under /admin/rcontrol. |
|
| rs232sigin | Prints status of the signalin pin of the serial interface. | |
| scanzeroconf | Scans for cameras with Zero Configuration Networking enabled. Scan time is set through parameter time. Default scan time is five seconds. Only available as administrator under /admin/rcontrol. |
|
| sendmessage | Sends a network message (IP Notify) specified in the message parameter to the IP address specified in the addr parameter. |
|
| push | Send a push notification specified in the message parameter using a push profile. |
|
| set_plex_recording_target | Reconfigures event recording to use a specified target on an expansion device. Either specify the target directly via the target parameter, or indirectly by requesting a specific media_type such as cf, sd or usb. Then store to flash and reboot in order to activate changes. Only available as administrator under /admin/rcontrol. |
|
| set_plex_recording_target_and_reboot | Same as set_plex_recording_target. Also stores the new configuration into flash and reboots the camera. Only available as administrator under /admin/rcontrol. |
|
| settime | Sets the current system time. Specify the time in seconds since the epoch. If in NTP client mode, triggers a resync to the time server; the time parameter is optional in this case. Only available as administrator under /admin/rcontrol. |
|
| sigout | Triggers the signal out profile as specified using the profile parameter. |
|
| sound | Play back a given sound profile or sound file. If both are given, the former takes precendece over the latter. |
|
| speakip | Outputs the camera's current IP address on the speaker. | |
| storeconfig | Stores the current configuration to flash. Only available as administrator under /admin/rcontrol. |
|
| test_fileserver | Runs a file server test. |
|
| userclick | Triggers a User Click (UC) event. | |
| voipcall | Triggers VoIP call-out using the sip address specified in the sipaddr parameter. |
|
| voiphangup | Hangs up VoIP call-out. | |
| voipphone | Triggers VoIP call-out using the profile specified by id or name. |
|
| voiprestart | Restarts the VoIP software of the camera. |
Please note that the following actions have become obsolete and are deprecated. They are still supported for legacy purposes.
"setrs232sig", "sigouthigh", "sigoutlow", "MxMessageSystem"